CBFJW - PROCESS 94BX-MR BLEACH-FIX REPLENISHER PART A, 283A
- MSDS: CBFJW
- Manufacturer: MILES INC
- Product Name: PROCESS 94BX-MR BLEACH-FIX REPLENISHER PART A, 283A
- National Stock Number: 6750-00N067084
Product Identification
Product ID:PROCESS 94BX-MR BLEACH-FIX REPLENISHER PART A, 283A
MSDS Date:10/01/1993
FSC:6750
NIIN:00N067084
Kit Part:Y
MSDS Number: CBFJW
Responsible Party
RIDGEFIELD PARK, NJ 07660
US
Emergency Phone: 303-623-5716;800-424-9300(CHEMTREC)
Info Phone: 201-440-2500
Cage: MILES
Contractor
Telephone: 800-662-2927
Cage: MILES
Ingredients
THIOSULFURIC ACID, DIAMMONIUM SALT; (AMMONIUM THIOSULFATE)
CAS: 7783-18-8
RTECS: XN6465000
Fraction By Weight: 40-45%
OSHA PEL N/K
ACGIH TLV: N/K
PYROSULFUROUS ACID, DISODIUM SALT; (SODIUM METABISULFITE)
CAS: 7681-57-4
RTECS: UX8225000
Fraction By Weight: 5-10%
OSHA PEL 5 MG/M3
ACGIH TLV: 5 MG/M3
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 45-50%
OSHA PEL N/K
ACGIH TLV: N/K
ACETIC ACID (CERCLA)
CAS: 64-19-7
RTECS: AF1225000
OSHA PEL 10 PPM
ACGIH TLV: 10 PPM; 15 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: (NOTE:PERTAINS TO FINISHED
PRODUCT) EYE/SKIN CONTACT: MAY CAUSE IRRITATION. INHALATION:
NORMALLY NO PROBLEM, BUT INHALATION OF MIST COULD CAUSE RESPIRATORY
IRRITATION. INGESTION: MAY CAUSE IRRI TATION OF MUCOUS MEMBRANES OR
DIGESTIVETRACT. CHRONIC: (NOTE: PERTAINS TO EACH INGREDIENT (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: LISTED PER 29 CFR 1910.1200) A
COMPUTERIZED LITERATURE SEARCH OF NATIONAL DATABASES DID NOT YIELD
ANY CHRONIC EFFECTS ASSOCIATED WITH THESE MATERIALS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: IMMEDIATELY FLUSH WITH PLENTY OF RUNNING WATER FOR AT
LEAST 15 MINUTES. OBTAIN MEDICAL ATTENTION. SKIN: FLUSH AFFECTED
AREAS PROMPTLY WITH WATER FOR 15 MINUTES. REMOVE CONTAMINATED
CLOTHING. IN CASE OF CONTINUED IRRITATION CONSULT MD. INHALATION:
REMOVE TO FRESH AIR. INGESTION: OBTAIN IMMEDIATE MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . EVACUATE PERSONNEL TO A SAFE AREA. KEEP
PERSONNEL REMOVED AND UPWIND OF FIRE.
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION EMISSION OF
TOXIC FUMES OF SO*2 IS POSSIBLE. SOME OF THESE MATERIALS MAY BURN
BUT NONE OF THEM IGNITES READILY.
Accidental Release
Spill Release Procedures:NOTE:REVIEW FIRE FIGHTING & SPEC PROT INFO
BEFORE PROCEEDING W/CLEAN UP. USE APPROP PERSONAL PROT EQUIP DURING
CLEAN UP. DIKE SPILL. PVNT LIQ FROM ENTERING SEWERS, WATERWAYS OR
LOW AREAS. SOAK UP W/SA WDUST, SAND, OIL DRY OR OTHER ABSORB MATL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID EYE AND SKIN CONTACT AND STORE
IN WELL-VENTILATED AREA. KEEP CONTAINER TIGHTLY CLOSED. DO NOT
STORE WITH INCOMPATIBLE MATERIALS.
Other Precautions:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO IN
AREA WHERE THEY MAY BECOME CONTAMINATED WITH THIS MATERIAL.
Exposure Controls
Respiratory Protection:NONE NEEDED WITH WORKING MIXTURES AND NORMAL
ROOM VENTILATION (10 CHANGES OF AIR PER HOUR). USE NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:ROOM VENTILATION IS SUFFICIENT. AVOID USE OF PROD IN
UNVENTILATED AREAS. ALWAYS CONTROL AIRBORNE LEVELS BELOW (SUPDAT)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . FOR
SKIN PROT USE CHEM RESISTANT GLOVES & APRONS. DISPOSABLE (SUPDAT)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
WASTE DISP METH: TO SEWER REQS APPROVAL OF PERMITTING AUTH & MAY REQ
PRETREATMENT. VENT: THE EXPOSURE GUIDELINES (USE 50% OF THE TLV).
OTHER PROT EQUIP: COVERALLS ARE OPTIONAL & DISCARD AFTER USE.
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.309 (H*2O=1)
pH:5.50
Solubility in Water:100% (BY WEIGHT)
Appearance and Odor:CLEAR AND COLORLESS LIQUID; AMMONIA ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ALKALI.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF SULFUR, AMMONIA.
Disposal
Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS .
RECOVER NONUSABLE FREE LIQ &/OR CONTAMD WATER & DISPOSE OF IN
APPRVD & PERMITTED TREATMENT SYS. REMOVE NONUSABLE SOLID MATL &/OR
CONTAMD SOIL FOR DISP IN APPRVD & PERMITTED LANDFILL. DISCHARGE
(SUPDAT)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.